Shanghai Anping Static Technology Co.,Ltd 86-021-6451-7662 journey@sh-anping.com.cn
SUS Electrode 20W Ion Bar Electrostatic Eliminator

SUS Electrode 20W Ion Bar Electrostatic Eliminator

  • High Light

    Ion Bar Electrostatic Eliminator

    ,

    20W Electrostatic Eliminator

    ,

    SUS Electrode Electrostatic Eliminator

  • Model No.
    AP-AB1103
  • Working Voltage
    AC5600V(<1000mm);AC7000V(Length≥1m)
  • Power
    20W
  • Electrode
    SUS
  • Ion Balance
    ≤|±150V|(AVE)
  • Decay Time
    ≤1.0S(working Distance100mm)
  • Accessory
    M4×20 Screw Bolt
  • Warranty
    1 Year
  • Function
    Easy To Remove High Voltage Static Electricity
  • Product Name
    Static Neutralizing Bar
  • Application
    Anti Static Eliminator For Printing Machine
  • Hv Cable Length
    2m
  • Dimension
    L*W*H(150mm→3000mm)*20.4mm*32mm
  • Bar Material
    Flame Retardant PVC、AL
  • Power Supply
    AP-AY1505/ AP-AY2505(Length <1m): AP-AY1502/ AP-AY2502(Length≥1m):
  • Place of Origin
    China
  • Brand Name
    AP&T
  • Certification
    CE
  • Model Number
    AP-AB1103
  • Minimum Order Quantity
    1 piece
  • Price
    Negotiate
  • Packaging Details
    In cartons
  • Delivery Time
    5 working days
  • Payment Terms
    T/T, Western Union, MoneyGram,PayPal,cash
  • Supply Ability
    1000 pieces per month

SUS Electrode 20W Ion Bar Electrostatic Eliminator

Bar Shape Static Eliminator AP-AB1103 AC Electroshock-proof Anti Static Bar

 

 

Product Feature

 

(1)Bar shaped and cross over static eliminator

(2)Compact structure and elegant appearance

(3)Working under high voltage and micro current (μA level)

(4)Electroshock-proof function

(4)Stripe shaped notch on the back of the bar for user to fasten the bar

 

 

Specification

 

Model No. AP-AB1103
Working voltage AC5600V(<1000mm);AC7000V(Length≥1m)
Power 20W
Working way AC
Electrode SUS
Discharge structure Resistance coupling
Discharge range L*W*H(150mm→3000mm)*300mm*100mm
Working distance 30-150mm
Ion balance ≤|±150V|(AVE)
Decay time ≤1.0S(working distance100mm)
Working temperature 0°C - 50°C
Working humidity <70%
Dimension L*W*H(150mm→3000mm)*20.4mm*32mm
Bar material Flame retardant PVC,AL
Accessory M4×20 screw bolt
Power supply

AP-AY1505/ AP-AY2505(Length <1m):

AP-AY1502/ AP-AY2502(Length≥1m):

HV cable 2.5m(can do customize,Max10m)
Warranty 1 Year
Certificate CE

 

Test standard:ANSI/ESD.STM3.1,ANSI/ESD.SP3.3,SJ/T 11446—2013

Test Device:Trek157 static detector

Test Voltage:±1000V → ±100V attenuation

Test environment:Humidity 50±5%;Temperature23±3℃

 

Safety warning

1. Please read the instruction manual carefully before installing and using this equipment.

2. The entire set of equipment must be reliably grounded during use, otherwise it is easy to cause abnormal or even damage to the ion rod.

3. It is not suitable to use this equipment in the environment with> 70% humidity.

4. It is strictly forbidden to use this equipment in flammable and explosive environments.

5. Unauthorized disassembly of the product is strictly prohibited, and internal maintenance and repairs must be performed by professionals.

6. The product is strictly prohibited from touching water stains, otherwise an abnormality may occur, resulting in electric shock or fire.

7. Check or replace the product, you must turn off the power, otherwise it may cause electric shock or fire.

8. The product is specially designed for removing static electricity. Other uses are strictly prohibited. Any abnormal use may cause hidden troubles such as machine failure, electric shock and fire.

9. It is strictly forbidden to touch the electrode needle when it is energized, otherwise it may cause malfunction and electric shock accident.

10. The discharge needle is a sharp metal object, please use it carefully.

11. Before the product is powered on, please check the specifications of the power supply. Any power supply that does not meet the specifications will cause damage or even failure to the product.

12. Please check the product power line / communication line regularly, and replace it immediately if it is damaged, otherwise it may cause problems such as leakage, poor communication and abnormal operation.

 

Trouble shooting table:

NO Problem Possible reason Solution
1 Discharge ability is significantly reduced Discharge needle pollution and damage Clean or change the ion bar
Install position is not good Find the best install position
2 Discharge ability is reduced There are conductors or other ion bars around the ion bar Remove the conductors or other ion bars
3 No discharge HV cable is damaged Return to factory
Ion bar insulation damage Return to factory
Poor grounding / no grounding Check the electrical grounding of ion bars and plant equipment
4 Product burned ion rod insulation damage Return to factory
 

 

SUS Electrode 20W Ion Bar Electrostatic Eliminator 0

General

 

AP-AB1103 ion bar is the bar shape static eliminator developed by Shanghai Anping Static Technology Co.,Ltd.

 

AP - AB1103 ion bar generates positive and negative ion on emitter by AC high voltage and transfer the ion by pressed air to the object surface to be static removed. Thus neutralize the ion on the object surface and eliminate static efficiently and reliably. .

It is widely used in electronics, plastics, chemicals, printing, textile, optical and other industries.

 

SUS Electrode 20W Ion Bar Electrostatic Eliminator 1

Industry Application

Can be used in electronics, plastics, chemicals, printing, textile, optical and other industries.

SUS Electrode 20W Ion Bar Electrostatic Eliminator 2


SUS Electrode 20W Ion Bar Electrostatic Eliminator 3

 

◆ Maintenance

1. In order to ensure the good performance of the product, it should be cleaned and maintained in time according to the use environment and the required electrostatic protection requirements, that is: use an electrostatic brush, a dust-free cotton swab, a dust-free cloth dipped in anhydrous alcohol, and gently remove it. The performance of carbon deposits on electrodes, discharge sockets and metal discharge bodies will be significantly improved. note:

A. It must be operated 10 minutes after the power is turned off.

B. Ion rods must be cleaned when dust or white products appear on the needle tip during use. When the brush can not meet the cleaning requirements, you can use a clean cotton swab dipped in absolute alcohol for cleaning.

C. After cleaning, you must wait for the alcohol to completely volatilize before working with electricity. Do not use any other organic solvents to clean the stick.

2. If the work indicator light of the power supply insertion port on the stick panel is off, it should be stopped and checked and repaired by professional maintenance personnel. It can be used only after the electrical performance indicators are normal.

 

◆ After-sale service

The AP-AB1103 ion bar has undergone rigorous test inspection and aging treatment before leaving the factory, and its performance has fully reached the relevant indicators marked in the instruction manual.

1. AP & T makes the following promise to users: Within one year from the date of purchase, our company will repair or replace any parts that have been defective after inspection by our company free of charge. However, this commitment does not apply to the following situations:

(1) The equipment is misused and installed;

(2) Damage caused by negligence or accident during use;

(3) Self-modified, disassembled or repaired by other non-Anping authorized service department.

2. The alloy electrode is a consumable item, which is not covered by the warranty. The company must charge a replacement for maintenance.

4. Except for the repair or replacement of parts within this provision, AP & T does not undertake any obligations and related responsibilities of product users.

 

◆ Packing accessories

1.Instruction manual

2. Certificate of conformity

3.M4 screw bolt(Length <1m *2; each 0.5m add 1)