SUS 20W Explosion Proof AC 4000V Static Eliminator

SUS 20W Explosion Proof AC 4000V Static Eliminator

  • High Light

    Explosion Proof Static Eliminator

    ,

    AC 4000V Static Eliminator

  • Product Name
    AP-AB1602A
  • Explosion-proof Certificate No.
    GYB16.1549X
  • Ion Emission
    Power Frequency AC
  • Transmitting Electrode
    SUS
  • Power
    20W
  • Electrode High Voltage
    ≤4000V
  • Electrode Pin Combined Capacitor
    <3.5pF
  • Power Consumption Range
    L*W*H(110mm→3000mm)*300mm*600mm
  • Installation Distance
    100-600mm
  • Air Pressure
    ≤0.6MPa
  • With Throttle Air Source Connector
    Φ8-G1/8 Red
  • Ion Balance
    ≤|±300V|
  • Place of Origin
    China
  • Brand Name
    AP&T
  • Certification
    CE
  • Model Number
    AP-AB1602A
  • Minimum Order Quantity
    1 pcs
  • Packaging Details
    Standard Export Packing (Carton)
  • Delivery Time
    3-7 working days after payment
  • Payment Terms
    T/T, Western Union, MoneyGram,PAYPAL
  • Supply Ability
    1000 pieces per month

SUS 20W Explosion Proof AC 4000V Static Eliminator

AP-AB1602A Anti Static Bar 20W Explosion-proof AC 4000V Voltage Static Eliminator

 

Product description

AP-AB1601A / AP-AB1602A explosion-proof AC voltage static eliminator is a rod type static elimination device developed by Anping Company (AP & T) to eliminate static electricity on the surface of objects.

The product explosion-proof mark is Ex s ⅡB T4 Gb, and the explosion-proof certificate number is GYB16.1549X.

Can be widely used in printing, plastic, textile and other industries with flammable conditions.

 

Special conditions for product security

The explosion-proof certificate number suffix "X" indicates that the product has special conditions for safe use, as follows:

1. The product should not be used in places where conductive objects may adhere to static electricity electrodes (cannot be used if the static electricity electrodes may adhere to conductive objects such as carbon and metal foil).

2. The static electricity electrode should be installed at least 20mm away from the static electricity removal object.

3. The distance between the static elimination electrode and the mechanical frame should be more than 10mm.

4. Keep the anti-static electrode clean. It is strictly forbidden to dry-clean the electrode holder.

5. The power supply unit does not have an explosion-proof structure and must be installed in a non-hazardous place.

6. The length of the high-voltage cable is up to 8m.

7. Never open the cover.

8. It is forbidden to rub the surface of the product shell to prevent the danger of ignition due to static electricity.

 

Product structure features and working principles

(1) Structural characteristics:

1. It is a rod-type, horizontal active static eliminator.

2. The stick is small and exquisite.

3. Work under high voltage and micro current (μA level).

4, with anti-shock function, to avoid accidental human body contact and cause injury.

5. It has a certain anti-flammability function, which can be applied to places with flammable and explosive conditions corresponding to Ex s ⅡB T4 Gb or lower.

6. Special bar notch on the back of the body, the mounting bolt can be moved.

(2) working principle:

AP-AB1601 / AP-AB1602 explosion-proof AC voltage static eliminator uses high-frequency AC high-voltage, and acts on a dedicated transmitting electrode through an impedance coupling device to ionize air molecules and generate positive and negative high-voltage ions; and transport them to the static elimination The surface of the object neutralizes the positive and negative electrostatic charges to achieve the purpose of efficient and reliable elimination of static electricity.

 

Product technical specifications:

Type AP-AB1601A AP-AB1602A
Explosion-proof sign Ex s ⅡB T4 Gb Ex s ⅡB T4 Gb
Explosion-proof certificate No. GYB16.1549X GYB16.1549X
Operating Voltage Power frequency AC4000V Power frequency AC4000V
Power 20W 20W
Ion emission Power frequency AC Power frequency AC
Transmitting electrode SUS SUS
Discharge structure Resistance coupling Resistance coupling
Electrode high voltage ≤4000V ≤4000V
Electrode pin combined capacitor <3.5pF <3.5pF
Power consumption range L*W*H(110mm→3000mm)*300mm*100mm L*W*H(110mm→3000mm)*300mm*600mm
Installation distance 30-100mm 100-600mm
Air pressure —— ≤0.6MPa

With throttle

Air source connector

—— Φ8-G1/8 Red
Ion balance ≤|±300V| ≤|±300V|
Discharging speed ≤2.5S (Different test conditions will result in different test data) ≤2.5S (Different test conditions will result in different test data)
Operating temperature 0°C – 50°C 0°C – 50°C
Working humidity <70% <70%
Rod material Flame retardant PVC,AL Flame retardant PVC,AL
Dimensions L*W*H(110mm→3000mm)*20.4mm*32mm L*W*H(110mm→3000mm)*28.6mm*38.7mm
Installation accessories Hex Bolts M4*20 Hex Bolts M5*20
Supporting power AP-AY1603/2603 AP-AY1603/2603
High-voltage connection line length 2.5m(Can be customized according to requirements, the maximum length is 8m) 2.5m(Can be customized according to requirements, the maximum length is 8m)
Warranty period 1 year 1 year
Certification CE CE

Working way

SUS 20W Explosion Proof AC 4000V Static Eliminator 0

 

External dimensions illustration:

SUS 20W Explosion Proof AC 4000V Static Eliminator 1SUS 20W Explosion Proof AC 4000V Static Eliminator 2SUS 20W Explosion Proof AC 4000V Static Eliminator 3

Operational guidance

1. Select the best power consumption location, and install the rod body and supporting high-voltage power supply firmly.

2. Insert the high-voltage plug of the connecting rod into the matching high-voltage power supply output socket.

3. Connect the ground terminal of the rod to the ground stud of the high voltage power supply.

4. Connect the air source connector of the rod body (air source type) to the air source generator and turn on the air source switch.

5. Turn on the power switch, the switch indicator light will show the power supply work, adjust the appropriate air source pressure, and make the positive and negative air ions generated at the electrode needle to neutralize the surface of the object.

 

Warning: When using a compressed air source, ensure that the gas entering the ion wind rod is dry and clean to avoid water vapor, grease, and dust from the air source contaminating the electrode needles and causing high-voltage insulation failures, affecting normal use.

 

Failure analysis and elimination

NO. Failure phenomenon Cause Analysis Method of exclusion Remark
1 Put the electrode to the ground electrode on the side of the bar to ignite Reduced surface insulation resistance due to bar volume ash Power off the cleaning bar In order to ensure the good performance of this product, according to the use environment and the required electrostatic protection requirements, Regularly use an electrostatic brush, dust-free cotton swab, and dust-free cloth to dip in absolute alcohol to gently remove carbon deposits on the discharge electrode and rod.
2 Discharge electrode to other metal grounding body The bar installation position is too close to other metal grounding bodies In order to ensure the safe use and power dissipation performance, the installation position of the bar should be moved, and it should be more than 50mm away from other metal grounding bodies.
3 Significantly reduced static elimination performance Discharge needle contamination and damage Clean or replace the ion bar
Incorrect orientation of the ion bar Confirm the best installation position
4 Reduced static elimination performance There are conductors or other ion bars around the ion bar Remove (moving) conductors or other ion bars
5 Unable to discharge Damaged high-voltage connection line Return to factory
Ion bar insulation is damaged Return to factory
Poor ground / no ground Check the electrical grounding of ion bars and plant equipment
6 Product burnout Ion bar insulation is damaged Return to factory
 

Maintenance

1. Do not disassemble the device.

2. Do not short-circuit the high-voltage power line to avoid permanent damage to the power supply.

3. Please check the power cord of the product regularly. If it is damaged, please replace it immediately, otherwise it may cause leakage and abnormal working.

4. The power supply should be stored in a cool and dry environment.

5. When abnormality or problem is found during the use of the power supply, stop using it immediately and send the power supply to Anping Company for processing.

SUS 20W Explosion Proof AC 4000V Static Eliminator 4

After sales service

1. AP-AB1601A / AP-AB1602A explosion-proof AC voltage static eliminator has undergone strict testing and aging treatment before leaving the factory, and its performance fully meets the relevant indicators marked in the instructions.

2. AP & T promises to users as follows: Within one year from the date of purchase, the company repairs or replaces any spare parts that have been inspected for defects by the company free of charge. However, this commitment does not apply to the following situations:

(1) The equipment has been altered, misused, or installed;

(2) Damage caused by negligence or accident such as incorrect input voltage;

(3) Disassemble or repair by yourself or have been repaired by other service departments.

3. Except for the repair or replacement of the parts specified here, AP & T does not assume any obligations and relevant responsibilities of the product user.

Attachments

1. Warranty card

  • Instruction
  • Certificate of conformity

4. AP-AB1601A M4 mounting bolts (2 bolts within 1 m of rod length, each 0.5 m increase in rod length, 1 additional bolt) 2 bolts within 1m, each bolt length increases by 0.5m, an additional bolt)