Send Message
Shanghai Anping Static Technology Co.,Ltd 86-021-6451-7662 journey@sh-anping.com.cn
Proof Shock Ion Bar ESD Ionizer AP-AB1215 With 200mm None Air Source

Proof Shock Ion Bar ESD Ionizer AP-AB1215 With 200mm None Air Source

  • High Light

    esd air ionizer

    ,

    electrostatic discharge ionizer

  • Name
    Proof-shock Ion Bar
  • Output Voltage
    DC±5.00(KV)
  • Output Frequency
    5, 30Hz (default)
  • Power
    10W
  • Ion Balance
    ≤|±30V| (AVE)
  • Discharge Time
    ≤1S
  • Note
    USD12.0 Per Additional 100mm
  • ◆Product Feature
    Remote Control Ion Output
  • Motor
    AC Pulse
  • Place of Origin
    Shanghai,China
  • Brand Name
    AP&T
  • Certification
    CE
  • Model Number
    AP-AB1215
  • Minimum Order Quantity
    1 piece
  • Price
    USD 322 / piece
  • Packaging Details
    in cartons
  • Delivery Time
    3-10 days after payment
  • Payment Terms
    L/C,, T/T, Western Union, MoneyGram,Paypal
  • Supply Ability
    500 pieces per month

Proof Shock Ion Bar ESD Ionizer AP-AB1215 With 200mm None Air Source

Proof-shock Ion Bar AP-AB1215 with 200mm None Air Source

Proof Shock Ion Bar ESD Ionizer AP-AB1215 With 200mm None Air Source 0Proof Shock Ion Bar ESD Ionizer AP-AB1215 With 200mm None Air Source 1

Product Feature

1.Bar shaped and cross over static eliminator

2.Adjustable positive and negative ion output rate

3.Manufactured by using the latest patented technology of static removing

4.Fast speed of static removing, low ion balance and high safety

5.Adjustable positive and negative ion frequency

6.With alarm function of high voltage fault

7.Remote control ion output

8.Shock-proof function prevent user from being electric shocked

9.Support integrate control ,easy to operate.

 

Specification

Model AP-AB1215
Output voltage DC±5.00(KV)
Output frequency 5, 30Hz (default)
Duty factor 10%-90%
Power 10W
Working distance 100-1000mm
Ion balance ≤|±30V| (AVE)
Discharge time ≤1S
Working temperature 0℃-50℃
Working humidity <70%
Bar Width 335-410mm(spacing 25mm);460-2960(Spacing 50mm)
Note USD12.0 Per additional 100mm

 

 

Testing instrument :3M-711 Static tester

Testing standard:ESD.STM3.1-2000;SJ/T 11446—2013

Testing voltage :±1000 — ±100V Attenuation

Testing environment :Humidity50±5% Temperature:23±3℃

 

Testing data as below(Testing distance:100mm,Ion bar width;200mm,Frequency:30Hz):

 

Proof Shock Ion Bar ESD Ionizer AP-AB1215 With 200mm None Air Source 2Proof Shock Ion Bar ESD Ionizer AP-AB1215 With 200mm None Air Source 3

 

General 

AP-AB1216 Air source AC pulse ion bar is the newest developed bar type static eliminator for static removing.

It can be widely used in electronics, plastics, chemicals, printing, textile, optical and other industries.

 

Features 

  • Bar shaped and cross over static eliminator
  • Manufactured by using the latest patented technology of static removing.
  • Fast speed of static removing, low ion balance and high safety.
  • LCD on bar body indicates working status for easy use and maintenance
  • Output voltage adjustable, fit for different static environment.
  • With alarm function of ion volume, electrode tip cleaning and high voltage fault.

Parameter 

Model AP-AB1216
Output voltage DC±5.00(KV)
Output frequency 30Hz(default)
Duty factor 10%-90%
Power 10W
Working distance 100-1000mm
Ion balance ≤|±30V|
Discharge time ≤2S(adjust)
Working temperature 0℃-50℃
Working humidity <70%
Air pressure scope 0.1-0.6MPa
Cord length 2.5m
Bar length 385mm,410mm,460mm,510mm……2510mm(spacing distance 50mm)
 

Notice on use and safety warning 

 

  • Read this manual carefully before installing and using of the device.
  • Be sure the device reliable ground connected during use, otherwise may cause bar body burn.
  • Touching of electrode tip during use strictly prohibited.
  • Do not use this device in the environment where the humidity is greater than 75%.
  • Input air must be clean and filled air without water, oil and dust particle
  • It is strictly prohibited to use this equipment in combustible and explosive environment.
  • Internal maintenance and repair must be carried out by professionals

 

Installation guide

  • Choose optimal location for discharge and fix the bar and power supply steadily.
  • Connect earth to earth connect end on ion bar.
  • Insert one end of the power cord into power adapter and the other end into power port.
  • Connect air connector to air supply device with tube and turn on the air switch.
  • Turn on the power switch and adjust proper air pressure.

Maintenance 

  • User should clean and maintain timely to ensure the good performance of the product according to working environment and requirement of ESD protection. Clean the carbon materials on electrode tip, discharge pad and metal discharge body with static brush or clean cloth with ethanol can obviously improve the performance.

Caution:

  • Must be done after the power is shut done for 10 minutes
  • Restart must wait till alcohol completely volatilized after cleaning by clean cloth with ethanol. Any other organic solution is not allowed to be used to clean the rod.
  • Stop using when POS/NEG working indication keeps off. Re-use after check and repair by professionals.