Shanghai Anping Static Technology Co.,Ltd 

 

16 Years of ESD Experience Creating Excellent Quality 

 

Email:journey@sh-anping.com.cn           Phone:0086 21 64517752

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsESD Ionizer

Proof Shock Ion Bar ESD Ionizer AP-AB1215 With 200mm None Air Source

Proof Shock Ion Bar ESD Ionizer AP-AB1215 With 200mm None Air Source

    • Proof Shock Ion Bar ESD Ionizer AP-AB1215 With 200mm None Air Source
    • Proof Shock Ion Bar ESD Ionizer AP-AB1215 With 200mm None Air Source
  • Proof Shock Ion Bar ESD Ionizer AP-AB1215 With 200mm None Air Source

    Product Details:

    Place of Origin: Shanghai,China
    Brand Name: AP&T
    Certification: CE
    Model Number: AP-AB1215

    Payment & Shipping Terms:

    Minimum Order Quantity: 1 piece
    Price: USD 322 / piece
    Packaging Details: in cartons
    Delivery Time: 3-10 days after payment
    Payment Terms: L/C,, T/T, Western Union, MoneyGram,Paypal
    Supply Ability: 500 pieces per month
    Contact Now
    Detailed Product Description
    Name: Proof-shock Ion Bar Output Voltage: DC±5.00(KV)
    Output Frequency: 5, 30Hz (default) Power: 10W
    Ion Balance: ≤|±30V| (AVE) Discharge Time: ≤1S
    Note: USD12.0 Per Additional 100mm ◆Product Feature: Remote Control Ion Output
    Motor: AC Pulse

    Proof-shock Ion Bar AP-AB1215 with 200mm None Air Source

    Proof Shock Ion Bar ESD Ionizer AP-AB1215 With 200mm None Air SourceProof Shock Ion Bar ESD Ionizer AP-AB1215 With 200mm None Air Source

    Product Feature

    1.Bar shaped and cross over static eliminator

    2.Adjustable positive and negative ion output rate

    3.Manufactured by using the latest patented technology of static removing

    4.Fast speed of static removing, low ion balance and high safety

    5.Adjustable positive and negative ion frequency

    6.With alarm function of high voltage fault

    7.Remote control ion output

    8.Shock-proof function prevent user from being electric shocked

    9.Support integrate control ,easy to operate.

     

    Specification

    Model AP-AB1215
    Output voltage DC±5.00(KV)
    Output frequency 5, 30Hz (default)
    Duty factor 10%-90%
    Power 10W
    Working distance 100-1000mm
    Ion balance ≤|±30V| (AVE)
    Discharge time ≤1S
    Working temperature 0℃-50℃
    Working humidity <70%
    Bar Width 335-410mm(spacing 25mm);460-2960(Spacing 50mm)
    Note USD12.0 Per additional 100mm

     

     

    Testing instrument :3M-711 Static tester

    Testing standard:ESD.STM3.1-2000;SJ/T 11446—2013

    Testing voltage :±1000 — ±100V Attenuation

    Testing environment :Humidity50±5% Temperature:23±3℃

     

    Testing data as below(Testing distance:100mm,Ion bar width;200mm,Frequency:30Hz):

     

    Proof Shock Ion Bar ESD Ionizer AP-AB1215 With 200mm None Air SourceProof Shock Ion Bar ESD Ionizer AP-AB1215 With 200mm None Air Source

     

    General 

    AP-AB1216 Air source AC pulse ion bar is the newest developed bar type static eliminator for static removing.

    It can be widely used in electronics, plastics, chemicals, printing, textile, optical and other industries.

     

    Features 

    • Bar shaped and cross over static eliminator
    • Manufactured by using the latest patented technology of static removing.
    • Fast speed of static removing, low ion balance and high safety.
    • LCD on bar body indicates working status for easy use and maintenance
    • Output voltage adjustable, fit for different static environment.
    • With alarm function of ion volume, electrode tip cleaning and high voltage fault.

    Parameter 

    Model AP-AB1216
    Output voltage DC±5.00(KV)
    Output frequency 30Hz(default)
    Duty factor 10%-90%
    Power 10W
    Working distance 100-1000mm
    Ion balance ≤|±30V|
    Discharge time ≤2S(adjust)
    Working temperature 0℃-50℃
    Working humidity <70%
    Air pressure scope 0.1-0.6MPa
    Cord length 2.5m
    Bar length 385mm,410mm,460mm,510mm……2510mm(spacing distance 50mm)
     

    Notice on use and safety warning 

     

    • Read this manual carefully before installing and using of the device.
    • Be sure the device reliable ground connected during use, otherwise may cause bar body burn.
    • Touching of electrode tip during use strictly prohibited.
    • Do not use this device in the environment where the humidity is greater than 75%.
    • Input air must be clean and filled air without water, oil and dust particle
    • It is strictly prohibited to use this equipment in combustible and explosive environment.
    • Internal maintenance and repair must be carried out by professionals

     

    Installation guide

    • Choose optimal location for discharge and fix the bar and power supply steadily.
    • Connect earth to earth connect end on ion bar.
    • Insert one end of the power cord into power adapter and the other end into power port.
    • Connect air connector to air supply device with tube and turn on the air switch.
    • Turn on the power switch and adjust proper air pressure.

    Maintenance 

    • User should clean and maintain timely to ensure the good performance of the product according to working environment and requirement of ESD protection. Clean the carbon materials on electrode tip, discharge pad and metal discharge body with static brush or clean cloth with ethanol can obviously improve the performance.

    Caution:

    • Must be done after the power is shut done for 10 minutes
    • Restart must wait till alcohol completely volatilized after cleaning by clean cloth with ethanol. Any other organic solution is not allowed to be used to clean the rod.
    • Stop using when POS/NEG working indication keeps off. Re-use after check and repair by professionals.
     

     

    Contact Details
    Shanghai Anping Static Technology Co.,Ltd

    Contact Person: Journey

    Tel: +8613870195985

    Send your inquiry directly to us (0 / 3000)