Self-Cleaning Suspended DC Eliminate Statics Overhead Ionizer Ionizing Air Blower

Self-Cleaning Suspended DC Eliminate Statics Overhead Ionizer Ionizing Air Blower

  • High Light

    static elimination blower

    ,

    industrial air ionizer

    ,

    self cleaning suspended ionizing blower

  • Discharge Speed
    <3s
  • Ion Balance
    -15V ~ + 15V (450mm Away From The Center Of The Air Outlet)
  • Power
    25W
  • Input Voltage
    220V/50HZ Or 110V/60HZ
  • Discharge Range
    1020*300*750mm(L*W*H)
  • Dimension
    1040*175*117.8mm(L*W*H)
  • Shell Material
    Aluminum Dusting
  • Ion Emission
    Steady DC
  • Place of Origin
    China
  • Brand Name
    AP&T
  • Certification
    CE
  • Model Number
    AP-DC2452-100C
  • Minimum Order Quantity
    1 pcs
  • Price
    negotiation
  • Packaging Details
    Standard Export Packing (Carton)
  • Delivery Time
    3 to 5 working days
  • Payment Terms
    T/T, Western Union, MoneyGram
  • Supply Ability
    2000 pcs / month

Self-Cleaning Suspended DC Eliminate Statics Overhead Ionizer Ionizing Air Blower

Self-cleaning Suspended DC Eliminate Statics Overhead Ionizer Ionizing Air Blower

 

Product Description

AP-DC2452-100C self-cleaning suspended ionizing air blower is one of the ionizing air blower series products produced by Anping Company (AP & T).

The AP-DC2452-100C self-cleaning suspended ionizing air blower uses positive and negative synchronous emitter electrodes. Corona discharge is generated by DC high voltage, ionizing air molecules, generating a large number of positive and negative air ions, and blown by the fan towards the Eliminate static electricity on the surface of the object.

Self-Cleaning Suspended DC Eliminate Statics Overhead Ionizer Ionizing Air Blower 0

Self-Cleaning Suspended DC Eliminate Statics Overhead Ionizer Ionizing Air Blower 1

 

Industry application

Can be widely used in electronics, optoelectronics, semiconductors and other industries.

 

Features

(1) It is suitable for eliminating static electricity in a large area.

(2) Multi-unit independent ion transmission port combination, fan stepless speed regulation.

(3) It has the function of automatic needle brushing at startup.

(4) Automatic needle brushing every 24 hours, eliminating manual brush cleaning and maintenance.

(5) The static elimination speed is fast and the circuit stability is good.

(6) The front and rear net covers are detachable for easy maintenance.

 

Technical specifications

Model AP-DC2452-100C
Operating Voltage ±DC4000-DC7000V
Input voltage AC220V / 50Hz or 110V / 60Hz
Power 25W
Ion emission Steady DC
Emitter electrode Tungsten alloy
Discharge structure Uncoupled electrical contact (discharge cylinder)
Discharge range 1020*300*750mm(L*W*H)
Discharge speed ≤3s (450mm perpendicular to the center of the air outlet)
Ion balance -15V ~ + 15V (450mm away from the center of the air outlet)
Alarm indication The power indicator is on and working normally
Air volume ≤4*89.1CFM
Noise ≤65db (150mm away from the air outlet)
Ozone concentration ≤0.05ppm (150mm away from the air outlet)
Operating temperature 0-50 ℃
Working humidity 30-70%RH
Dimensions 1040*175*117.8mm(L*W*H)
Shell material Aluminum dusting
Installation accessories 1 pair of L-shaped aluminum powder spraying mounting brackets, 1 pair of bakelite screw handles (M6 × 12)
Net weight 3100g (including accessories: 1 power cord, 1 mounting bracket, screw handle and gasket 2 kit.)
Gross weight 5150g
Quality assurance 1 year
Certification CE

Self-Cleaning Suspended DC Eliminate Statics Overhead Ionizer Ionizing Air Blower 2Self-Cleaning Suspended DC Eliminate Statics Overhead Ionizer Ionizing Air Blower 3

 

Test standards: ANSI / ESD.STM3.1, ANSI / ESD.SP3.3, SJ / T 11446—2013

Test equipment: Treak157 tester

Test voltage: ± 1000V → ± 100V attenuation

Test environment: relative humidity: 50 ± 5%; temperature: 23 ± 3 ℃;

Safety warning

1. Please read the instruction manual carefully before installing and using this equipment.

2. The entire set of equipment must be reliably grounded during use.

3. It is not suitable to use this equipment in the environment with> 70% humidity.

4. It is strictly forbidden to use this equipment in flammable and explosive environments.

5. Unauthorized disassembly of the product is strictly prohibited, and internal maintenance and repairs must be performed by professionals.

6. The product is strictly prohibited from touching water stains, otherwise abnormality will occur, resulting in electric shock or fire.

7. Check or replace the product, you must turn off the power, otherwise it may cause electric shock or fire.

8. The product is specially designed to eliminate static electricity, and other uses are strictly prohibited. Any abnormal use may cause hidden troubles such as machine failure, electric shock, and fire.

9. It is strictly forbidden to touch the electrode needle when it is energized, otherwise it may cause malfunction and electric shock accident.

10. The discharge needle is a sharp metal object, please use it carefully.

11. Before the product is powered on, please check the specifications of the power supply. Any power supply that does not meet the specifications will cause damage or even failure to the product.

12. Please check the product power line / communication line regularly, and replace it immediately if damaged, otherwise it may cause problems such as leakage, poor communication and abnormal operation.