Shanghai Anping Static Technology Co.,Ltd 86-021-6451-7662 journey@sh-anping.com.cn
RJ45 Interface RS485 DC Electrostatic Eliminator

RJ45 Interface RS485 DC Electrostatic Eliminator

  • High Light

    DC Electrostatic Eliminator

    ,

    RS485 Electrostatic Eliminator

    ,

    RJ45 Interface Static Electricity Eliminator

  • Model No
    AP-DJ1802
  • Input Voltage
    DC 24V (dual RJ45 Interface)
  • Input Current
    <0.6A
  • Output Voltage
    DC±5KV→±5.5KV
  • Power
    <14.5W
  • Ion Emission
    DC
  • Ozone Thickness
    ≤0.05ppm(150mm From Air Outlet)
  • Ion Balance
    ≤|±10V|
  • Discharge Speed
    ≤1.5S(300mm From Air Outlet)
  • Communication Method
    RS485
  • Installation Accessories
    1 Pair Of U-shaped Aluminum Powder Spraying Mounting Bracket, 2 Pairs Of Stainless Steel Screw Handles (M5 × 8)
  • Place of Origin
    China
  • Brand Name
    AP&T
  • Certification
    CE
  • Model Number
    AP-DJ1802
  • Minimum Order Quantity
    1 piece
  • Price
    usd148/pcs
  • Packaging Details
    In cartons
  • Delivery Time
    5 working days
  • Payment Terms
    T/T, Western Union, MoneyGram
  • Supply Ability
    1000 pieces per month

RJ45 Interface RS485 DC Electrostatic Eliminator

High Voltage AP-DJ1802 PULSE DC Static Electricity Eliminator Ionizing Air Blower

 

Features

1. 8 emitters makes high ion volume and fast decay time;

2. Auto-cleaning when switch on;

3. Default auto-cleaning time every 8 hours, Artificial emitter cleaning maintenance free;

4. Five gears of stable fan speed;

5. LED display shows ID address , fan speed and cleaning time;

 

6. Duty ratio of positive and negative ion output adjustable to adjust ion balance;

7. Auto balance with range ±10V.

 

9. Light & Voice alarm when fan default and ion balance abnormal;

10. 10. Remote control ion output When Plate or material surface with high positive static charge, Press “Fan+”“IB-”; When Plate or material surface with high Negative static charge, Press “Fan-”“IB+”

 

11. Support integrate control by PC, monitor working state of ion blower

12.CE certificated, with electromagnetic protection which will not cause electromagnetic interface to other equipment; It can also effectively avoid external electromagnetic interference and affect the normal operation of the fan.

 

Industry Application

Electronics, Plastic ,Chemical ,Printing, Optics Industry

 

 

Specification

Model No AP-DJ1802
Input voltage DC 24V (dual RJ45 interface)
Input current <0.6A
Output voltage DC±5KV→±5.5KV
Power <14.5W
Ion emission DC
Emitter electrode Tungsten
Discharge range 750*300mm(L*W)
Air volume <179CFM
Noise <75dBA(150mm from air outlet)
Ozone thickness ≤0.05ppm(150mm from air outlet)
Ion balance ≤|±10V|
Discharge speed ≤1.5S(300mm from air outlet)
Alarm indication

Boot instant-blue light

Normal working -Green light(Under monitoring)

Fan alarm -Red light flash with beeping

Ionization abnormal-Red light slow flash with beeping

Blue light blinks when infrared debugging

Working temperature 0℃-50℃
Working humidity <70%RH
Dimension 177*81*205.5mm(L*W*H)
Power adaptor

1. Interface power supply (default configuration):

INPUT: AC100—240V 50 / 60Hz;

OUTPUT: DC24V 2A (dual RJ45 interface)

2. Jack-type power supply (customized):

INPUT: AC100—240V 50 / 60Hz;

OUTPUT: DC24V 2A (5.5 * 2.5 single male head)

Integrated power supply

(Optional)

INPUT:AC100—250V 50/60Hz

OUTPUT: DC24V 2A (16 RJ45 interfaces)

Communication method RS485
Shell material Aluminum dusting
Installation accessories 1 pair of U-shaped aluminum powder spraying mounting bracket, 2 pairs of stainless steel screw handles (M5 × 8)
Weight Bare metal (including bracket) 1125g
Net weight (network cable, power cord, adapter, remote control) 1590g
Gross weight 2080g
Quality assurance 1Year
Certificate CE

 

RJ45 Interface RS485 DC Electrostatic Eliminator 0

RJ45 Interface RS485 DC Electrostatic Eliminator 1

Testing standard:ANSI/ESD.STM3.1,ANSI/ESD.SP3.3,SJ/T 11446—2013

Testing instrument:Trek157 Static tester

Testing voltage:±1000V → ±100VAttenuation

Testing environment :Humidity50±5%;Tempertaure:23±3℃

 

Notice on use and safety warning

 

  • Read this manual carefully before installing and using of the device.
  • Be sure the device reliable ground connected during use, otherwise may cause bar body burn..
  • Do not use this device in the environment where the humidity is greater than 75%.
  • Do not use this equipment in a flammable or explosive environment.
  • It is strictly forbidden to disassemble device without authorization. Internal maintenance and repair must be carried out by professionals.
  • Touch water is strictly forbidden, Otherwise will be electric shocked or fire.
  • Check or replace the product, you must turn off the power, otherwise it may cause electric shock or fire
  • The product is designed for static elimination. It is strictly forbidden to use for other purposes. Any abnormal use may cause machine malfunction, electric shock, fire and other hidden dangers.,
  • Do not touch the electrode needle when the power is on, otherwise it may cause malfunction and electric shock.
  • The emitter is a sharp metal object, please use it with care.
  • Before powering on the product, please check the specifications of the power supply. Any power supply that does not meet the specifications will cause damage or even failure
  • Please check the product power cord/communication line regularly. If it is damaged, please replace it immediately, otherwise it will cause problems such as leakage, poor communication and abnormal operation.

 

Installation guide

  • Installation:

Choose optimal location for discharge and fix the bar and power supply steadily..

Insert the adapter power cord into the ion fan power socket, and insert the 3pins power socket into the socket

Turn on the switch. The ion fan will automatically brush the needle. When the indicator light is green, the fan is normal working.