Send Message
Shanghai Anping Static Technology Co.,Ltd 86-021-6451-7662 journey@sh-anping.com.cn
Auto Clean Two Fan Overhead Ionised Air Blower

Auto Clean Two Fan Overhead Ionised Air Blower

  • High Light

    ionised air blower

    ,

    anti static blower

    ,

    DC12V static ionizer fan

  • Product Feature
    Auto Clean Two-fan Overhead Ionizing Air Blower
  • Working Voltage
    DC12V
  • Input Voltage
    AC220V 50HZ
  • Power
    25W
  • Discharge Time
    ≤3s(H 450mm To Center, 1000V ~100V Descent)
  • Ion Balancing
    ≤ ±10V(match ESD STM3.1-2000;IEC 61340-5-1 Standard)
  • Air Volume(adjustable)
    ≤2*90CFM
  • Noise
    ≤ 45db(150mm To Blower)
  • Ozone Thickness
    ≤0.01ppm (150mm To Nozzle Center)
  • Working Temperature
    0°C - 50°C
  • Effective Scope
    600*300*750mm(L*W*H)
  • Dimension And Weight
    640*175*118mm(L*W*H)
  • Place of Origin
    SHANGHAI,CHINA
  • Brand Name
    AP&T
  • Certification
    CE
  • Model Number
    AP-DC2452-60C
  • Minimum Order Quantity
    1 piece
  • Price
    USD 228/piece
  • Packaging Details
    in cartons
  • Delivery Time
    3-7 working days
  • Payment Terms
    T/T, Western Union, MoneyGram
  • Supply Ability
    1000 pieces per month

Auto Clean Two Fan Overhead Ionised Air Blower

AP-DC2452-60C Auto Clean Two-fan Overhead Ionizing Air Blower

 

Product Feature

 

1.Fit for static elimination in large area.

2.Auto cleaning function.

3.The combination of multi-units independent ion transmitting.

4.Stepless adjustment of the air volume and longer lifetime of the fan.

5.Fast speed of the elimination and stable performance of the circuit.

6.Detachable cover net both front and back, convenient to clean and maintain.

.

Auto Clean Two Fan Overhead Ionised Air Blower 0

Specification

 

Model AP-DC2452-60C
Working Voltage DC12V
Input Voltage AC220V 50HZ
Power 25W
Discharge time ≤3s(H 450mm to center, 1000V ~100V descent)
Ion Balancing ≤ ±10V(match ESD STM3.1-2000;IEC 61340-5-1 standard)
Air volume(adjustable) ≤2*90CFM
Noise ≤ 45db(150mm to blower)
Ozone thickness ≤0.01ppm (150mm to nozzle center)
Working temperature 0°C - 50°C
Effective scope 600*300*750mm(L*W*H)
Dimension and weight 640*175*118mm(L*W*H)

 

Testing instrument :3M-711 Static tester

Testing standard :SJ/T10694-2006,GB/T14437-97

Testing voltage :±1000 — ±100V Attenuation

Testing environment :Humidity30%—50% Temperature20±5℃

Auto Clean Two Fan Overhead Ionised Air Blower 1

Auto Clean Two Fan Overhead Ionised Air Blower 2

Industry Applications

 

Widely Used in electronics, optoelectronics, semiconductors, plastics, films and printing industries.

Auto Clean Two Fan Overhead Ionised Air Blower 3