Send Message
Shanghai Anping Static Technology Co.,Ltd 86-021-6451-7662 journey@sh-anping.com.cn
DC Desktop Industrial Static Eliminator AP-DJ1802 Ionizing air blower

DC Desktop Industrial Static Eliminator AP-DJ1802 Ionizing air blower

  • High Light

    anti static bar

    ,

    static electricity eliminator

  • Type
    AP-DJ1802
  • Input Voltage
    DC 24V (Double RJ45 Interface)
  • Input Current
    <0.6A
  • Output Voltage
    DC±5KV→±5.5KV
  • Power
    <14.5W
  • Ion Emission
    DC
  • Transmitting Electrode
    Tungsten
  • Discharge Range
    750*300mm(L*W)
  • Communication Method
    RS485
  • Shell Material
    Aluminum Dusting
  • Ion Balance
    ≤|±10V|
  • Place of Origin
    China
  • Brand Name
    AP&T
  • Certification
    CE
  • Model Number
    AP-DJ1802
  • Minimum Order Quantity
    1 pcs
  • Packaging Details
    Standard Export Packing (Carton)
  • Delivery Time
    3-7 working days after payment
  • Payment Terms
    T/T, MoneyGram
  • Supply Ability
    1000 Pieces per month

DC Desktop Industrial Static Eliminator AP-DJ1802 Ionizing air blower

AP-DJ1802 DC Desktop Industrial Static Eliminator Ionizing Air Blower

 

 

Product Features

1. 8 discharge electrodes, the amount of ions generated.

2. built-in pressurized axial fan, in addition to static speed.

3. with automatic boot brush function.

4. By default, the needle is automatically brushed once every 8 hours, eliminating the need for manual brush cleaning and maintenance.

5. fan five-speed speed regulation, stable performance.

6. with LCD display, can display device address, wind speed gear, cleaning cycle, as shown below.

7. with ion self-balancing function, self-balancing range ± 10V.

8. positive and negative ion output ratio adjustable, can be used for ion balance adjustment.

9. When the fan fails and the ion balance is abnormal, the sound and light alarms.

10. ion output characteristics, can be adjusted with the remote control.

11. It can realize online communication and monitor the working status of the fan.

12. Through the CE test, with electromagnetic protection, will not cause electromagnetic interference to other equipment; can also effectively avoid external electromagnetic interference affecting the normal operation of the fan.

13. The structure of the whole machine is modular, which is convenient for disassembly and maintenance.

Industry application

Can be widely used in electronics, semiconductor, optoelectronics and other industries.

DC Desktop Industrial Static Eliminator AP-DJ1802 Ionizing air blower 0DC Desktop Industrial Static Eliminator AP-DJ1802 Ionizing air blower 1

Performance parameter

Type AP-DJ1802
Input voltage DC 24V (Double RJ45 interface)
Input Current <0.6A
Output voltage DC±5KV→±5.5KV
Power <14.5W
Ion emission DC
Transmitting electrode Tungsten
Discharge range 750*300mm(L*W)
Air volume <179CFM
Audio noise <75dBA (150mm from the air outlet)
Ozone concentration ≤0.05ppm (150mm from the air outlet)
Ion balance ≤|±10V|
Discharge time ≤1.5S (300mm from the air outlet)
Alarm indication

1.At the moment of startup, clean operation - blue light flashes;

2.Normal work - green light (always in surveillance);

3.Fan alarm - the red light is always on;

4.Abnormal ion balance—red light flashes;

5.Blue flashing during infrared debugging

Communication method RS485
Operating temperature 0℃-50℃
Working humidity <70%RH
Dimensions 177*81*205.5mm(L*W*H)
Shell material Aluminum dusting
Mounting accessories 1 pair of U-shaped aluminum dust spray mounting bracket, 2 pairs of stainless steel screw handles (M5×8)
Adapter power supply

1, Interface power supply (default standard):

INPUT: AC100—240V 50/60Hz;

OUTPUT: DC24V 2A (double RJ45 interface)

2, Jack-type power supply (customized models):

INPUT: AC100—240V 50/60Hz;

OUTPUT: DC24V 2A (5.5*2.5 single male)

Integrated power supply

(optional)

INPUT:AC100—250V 50/60Hz;

OUTPUT: DC24V 2A (16 RJ45 connectors)

With wireless communication / RS485 / LAN communication function

Weight Bare metal (with bracket) : 1125g
Net weight (network cable, power cord, adapter, remote control) : 1590g
Gross weight : 2080g
Warranty 1Year
Certificate CE
DC Desktop Industrial Static Eliminator AP-DJ1802 Ionizing air blower 2
DC Desktop Industrial Static Eliminator AP-DJ1802 Ionizing air blower 3

Maintenance

1. In order to ensure the good performance of the product, the fan should be cleaned and maintained in time according to the use environment and the required static protection requirements. That is: use an electrostatic brush, a dust-free cotton swab, a dust-free cloth, and remove the anhydrous alcohol to gently remove it. Dust on the electrode, discharge bracket, fan, metal mesh cover. note:

A. It must be operated 10 minutes after the power is turned off.

B. During the use of the fan, the electrode needle cleaning cycle should be set according to the use environment; the more humid and dusty the environment, the appropriate cleaning cycle should be reduced.

C. After cleaning, the alcohol must be completely evaporated and then energized. Do not use any other organic solvent to clean the fan.

D. The alloy electrode is a consumable item and is not covered by the warranty. The company has to charge for the replacement of the customer.

2. Press the knob on each panel of the fan panel. The user should not press or rotate excessively. Otherwise, the device will be permanently damaged.

3. If the work indicator on the front panel of the fan is off or not lit, it should be stopped and repaired by professional maintenance personnel. It can be used after the electrical performance indicators are normal.

 

After-sale service

The AP-DJ 1802 DC ion fan has undergone rigorous testing and aging treatment before leaving the factory, and its performance fully meets the relevant indicators marked in the instructions for use.

AP&T makes the following commitments to the user: Within one year from the date of purchase, the company will repair or replace any parts that have been inspected by the company for free. However, this commitment does not apply to the following:

1. The device is misused and installed;

2. Inadvertent or accidental damage during use;

3. Self-modification, disassembly, or repair by other service departments not authorized by Anping.

AP&T assumes no responsibility or liability for product users other than repair or replacement of parts within this specification.

Packing accessories

1, The manual 2, the certificate 3, The adapter power supply

4, The national standard power cord 5, The remote control

6, The power connection network cable